Rockwell Automation manufactures the PanelView Plus 7 range of human-machine interface (HMI) devices. These gadgets give operators a graphical user interface a(GUI) to interact with machines and processes in industrial environments. Within this family, PanelView Plus 7 Standard and PanelView Plus 7 Performance are the two main varieties. Even though they both have certain things in common, they also differ greatly to meet various industrial needs and applications.

Overview of PanelView Plus 7

Allen Bradley PanelView Plus 7 Performance devices are intended for use as touch-based graphical operator interfaces in industrial automation environments. Through this interface, operators may keep an eye on and manage processes and machinery in a factory or production scenario. The gadgets are made to work with Allen-Bradley PLCs and other Rockwell control systems, and they support a variety of communication protocols.

PanelView Plus 7 Standard

For small- to medium-sized applications that need a simple HMI solution, PanelView Plus 7 Standard is made. The following are some salient characteristics:

Screen Sizes

PanelView Plus 7 Standard offers a range of screen sizes, from 4 to 15 inches, giving you the flexibility to meet the demands of varied applications. You can select a size from this selection that best fits your demands both visually and spatially.

Performance

For mild HMI applications, when simple visuals and animations are adequate, the Standard version is intended. Because it is less powerful than the Performance model in terms of processing power, it is appropriate for smaller-scale projects that do not require sophisticated data processing or visualization.

Communication

PanelView Plus 7 Standard is compatible with USB and Ethernet, two important communication technologies. For most basic HMI applications, this is sufficient to enable data transmission or system-to-system communication on the device. It might not, however, have as many connectivity choices as the Performance model, like more Ethernet ports or serial interfaces.

Operating System

Windows CE, a reliable operating system that provides fundamental HMI functions, powers the PanelView Plus 7 Standard. HMI interface design and management software, such as FactoryTalk View Machine Edition, can be reliably operated on this operating system.

Software

The Standard version of PanelView Plus uses FactoryTalk View Machine Edition to create HMI applications, just like other PanelView Plus devices. With the help of this program, which offers tools for graphics, animations, and other HMI features, you can create, test, and implement applications on the PanelView Plus 7 Standard.

Applications

The ideal uses for PanelView Plus 7 Standard are in small- to medium-sized industrial settings. These could be simple machine control interfaces, industrial automation systems, or other settings that require a simplified HMI solution. Because it is intended for less complex applications, it is an affordable choice for more straightforward installations.

Limitations

For smaller projects, the Standard model provides a reliable HMI solution, but its processing power and connectivity are constrained. Larger-scale or extremely complicated applications that call for sophisticated graphics, several connection protocols, or intensive data processing might not be a good fit for it.

PanelView Plus 7 Performance

The PanelView Plus 7 Performance is intended for use in more intricate and rigorous industrial settings. This is what makes it unique:

  • Screen Sizes: A range of screen sizes, from 7 to 19 inches, are also available in the Performance range; higher sizes are designed to accommodate more extensive applications.
  • Performance: The Performance model, as its name implies, is capable of handling more complicated visuals, animations, and data processing tasks due to its increased processing capacity. Applications requiring more complex data management and visualization are best suited for it.
  • Communication: More communication options, such as numerous Ethernet ports, USB, and serial connectors, are available with this model, enabling better connectivity with other systems and devices.
  • Operating System: The Performance model uses Windows CE as well, but because of its improved hardware, it can run larger applications.
  • Software: While still supporting FactoryTalk View Machine Edition, it has additional capacity to handle bigger projects and more complicated applications.

Choosing Between Standard and Performance

The particular requirements of your application will determine which of PanelView Plus 7 Standard and Performance is best for you. When space and money are factors, the Standard model is best suited for smaller applications with less complex HMI requirements. Conversely, larger, more intricate applications that demand sophisticated graphics, more processing power, and a wide range of networking options are better suited for the Performance model.

In conclusion, performance capabilities, connectivity options, screen widths, and adaptability for various application complexity are the main distinctions between PanelView Plus 7 Standard and Performance. Making the appropriate decision requires knowing the particular requirements of your project.